Description
Refurbished Oricare V8800 Ventilator Available for Purchase or Rental
- Pneumatically driven and electronically controlled
- ventilation
- Suitable for children and adults
- Easy control of the user interface and touch screen
- navigator wheel
- Sensible adjustable flow trigger and the trigger pressure
- Lung mechanics and flow monitoring loops
- 15 ” TFT color LCD
- synchronized nebulizer
- Wait inspiratory and expiratory
- manual inspiration
- intelligent suction
- Built-in battery ( ≥ 1 hour ) or optional extended
- battery (operation ≥ 2 hours)
- Just snap the ergonomic trolley available
- drawer with lock and auxiliary AC outlets
- Easily removable and sterilizable exhalation
- valve module
Ventilation Modes
- Pressure Control (PCV ) , Assist / Control
- Regulatory Volume Controlled Pressure ( PRVC )
- Assist / Control
- Synchronized intermittent mandatory
- Ventilation, SIMV (VCV ) + PSV , SIMV (PCV ) + PSV ,
- SIMV ( PRVC ) + PSV
- Spontaneous Ventilation ( SPONT / CPAP ) + PSV
- Bi Level Ventilation ( BIVENT / APRV ) + PSV
- Noninvasive ventilation ( NIV / CPAP + PSV ,
- NIV / PCV)
- Controlled Volume ( VCV ) , Assist / Control
Parameters and ranges
- Tidal volume 20 – 2500ml
- Respiratory Rate : 1-120 bpm
- Inspiration time : 0.2 -9
- Inspiratory pause time : 0 -4
- Tslope : 0- 2s
- FiO2 : 21 % ~ 100 %
- PEEP : 0 – 50cmH2O
- CPAP : 2 – 20cmH2O
- Psupport : 0 – 90cmH2O
- Pinsp 5 – 90cmH2O
- Esens : 5 % -80 %
- Flow patterns : square, decelerating
- expected inspiratory
- expected expiratory
- Nebulizer: 30 to 45 minutes
- Automatic tube compensation
- Compliance compensation
- graphic trends
- nurse call
monitoring
- The pressure values : Pmin , Pplat , Pmean , ppeak , PEEP
- Values of volume / flow : VTI , VTE , MV , MVspont , Leak %
- Loops: Flow – pressure , pressure – volume
- Flow – Volume
- FiO2
- Optional etCO2
alarms
MV high , MV low, Circuit disconnect , paw , high pressure leg of the continuing decline of the upper respiratory tract , VTi high, high fspont , TApnoea , high FiO2 , low FiO2 , EtCO2 high , EtCO2 chance supply low power , low battery, dead battery , failure of air supply , failure to supply O2, low PEEP .
Operating Conditions
- Gas Supply : O2 , Air , 200 kPa – 650Kpa ( 29 – 94PSI )
- Power supply: 100 -240V, 50 -60Hz
- Temperature: 10-40 (Operation )
- -20 To 60 ℃ (Storage)
- Relative humidity: 5-95 % , non-condensing
- (Operation )
- ≤ 95 % , non-condensing (storage)
- Atmospheric Pressure : 500hPa – 1060 hPa
- ( Operation and storage)
- Communication interfaces : RS232 , VGA , USB , RJ45
- Dimensions (H x W x D ) : 624x774x1410mm
standards
- UL / IEC 60601-1 , IEC 60601-1-2 , IEC 60601-2-12 , EN 794-1